AEPAmerican Electronic
Products. Inc.
GET A QUOTE
← HVAC PRODUCT FAMILIES
Pressure Controls

Pressure Controls

YK pressure switches provide discrete high-pressure, low-pressure, or vacuum control for HVAC and refrigeration equipment. Select the reset mechanism, contact arrangement, and process connection for the application.

REQUEST A QUOTE →

YK SPST auto-reset controls

Single-circuit pressure switches for high- and low-pressure protection in air conditioning, refrigeration and ice-making equipment.

  • A sealed stainless steel diaphragm opens or closes the contacts at a factory-set pressure and resets automatically at the reset point.
  • Normally open and normally closed versions are available with threaded flare or brazed tube connections and plug-in terminals or wire leads.
YK SPST auto-reset controls
Switch specifications
ParameterValue
Model codesYK-01H, YK-02H, YK-03H, YK-01L, YK-02L, YK-03L
Contact arrangementSPST, normally open or normally closed
Working pressure3–800 psi (0.02–5.5 MPa)
Burst pressure5,000 psi
Ambient temperature−30 to +80 °C
System medium temperature−50 to +120 °C
Electrical capacity125 VA at 24 VAC or 375 VA at 120/240 VAC
Dielectric strength, open contacts700 VAC for 1 s
Dielectric strength, terminal to shell2,000 VAC for 1 s
Rated-load life options30,000, 50,000 or 100,000 cycles
Safety proof pressure
Maximum working pressureProof pressure
Below 145 psi (1 MPa)250 psi (1.7 MPa)
145–400 psi (1–2.75 MPa)600 psi (4.1 MPa)
Above 400 psi (2.75 MPa)800 psi (5.5 MPa)
Switch outline drawings
Switch outline drawings
Pressure switch cross-sections
Pressure switch cross-sections
SPST contact diagrams
SPST contact diagrams

YK SPDT auto-reset controls

Changeover pressure switches for refrigeration and equipment requiring high- and low-pressure control.

  • A sealed stainless steel diaphragm transfers the common contact between the high and low terminals. The contacts return automatically at the reset point.
  • Choose factory-set pressures, threaded flare or brazed tube connections, and plug-in terminals or wire leads.
YK SPDT auto-reset controls
Switch specifications
ParameterValue
Model codesYK-01H, YK-02H, YK-03H, YK-01L, YK-02L, YK-03L
Contact arrangementSPDT changeover
Working pressure3–800 psi (0.02–5.5 MPa)
Burst pressure5,000 psi
Ambient temperature−30 to +80 °C
System medium temperature−50 to +120 °C
Electrical capacity125 VA at 24 VAC or 375 VA at 120/240 VAC
Dielectric strength, open contacts700 VAC for 1 s
Dielectric strength, terminal to shell2,000 VAC for 1 s
Rated-load life options30,000, 50,000 or 100,000 cycles
Safety proof pressure
Maximum working pressureProof pressure
Below 145 psi (1 MPa)250 psi (1.7 MPa)
145–400 psi (1–2.75 MPa)600 psi (4.1 MPa)
Above 400 psi (2.75 MPa)800 psi (5.5 MPa)
Switch outline drawings
Switch outline drawings
Pressure switch cross-sections
Pressure switch cross-sections
SPDT contact diagram
SPDT contact diagram

YK manual-reset controls

Manual-reset switches for high-pressure protection in air conditioning and refrigeration equipment.

  • A safety disc locks the contacts open after a trip. Once pressure drops, press the external reset button to reclose the circuit.
  • Pipe and panel mounting are available, with threaded flare or brazed tube connections and capillary options.
YK manual-reset controls
Switch specifications
ParameterValue
Contact arrangementManual reset
Working pressure145–800 psi (1–5.5 MPa)
Burst pressure5,000 psi
Ambient temperature−30 to +80 °C
System medium temperature−50 to +120 °C
Electrical capacity125 VA at 24 VAC or 375 VA at 120/240 VAC
Dielectric strength, open contacts700 VAC for 1 s
Dielectric strength, terminal to shell2,000 VAC for 1 s
Safety proof pressure
Maximum working pressureProof pressure
145–400 psi (1–2.75 MPa)600 psi (4.1 MPa)
Above 400 psi (2.75 MPa)800 psi (5.5 MPa)
Switch outline drawings
Switch outline drawings
Manual-reset cross-section
Manual-reset cross-section
Capillary and flare connector
Capillary and flare connector
Manual-reset contact diagram
Manual-reset contact diagram

YK vacuum controls

Automatic-reset switches for sub-atmospheric pressure protection in refrigeration and for pneumatic, hydraulic or lubrication control.

  • A sealed stainless steel diaphragm actuates the contacts at the factory-set pressure and resets automatically at the reset point.
  • Normally open and normally closed versions offer threaded flare or brazed tube connections and plug-in terminals or wire leads.
YK vacuum controls
Switch specifications
ParameterValue
Contact arrangementVacuum, normally open or normally closed
Working pressure15 inHg vacuum to 8 psi
Burst pressure2,500 psi
Ambient temperature−30 to +80 °C
System medium temperature−50 to +120 °C
Electrical capacity125 VA at 24 VAC or 375 VA at 120/240 VAC
Dielectric strength, open contacts700 VAC for 1 s
Dielectric strength, terminal to shell2,000 VAC for 1 s
Rated-load life options30,000, 50,000 or 100,000 cycles
Switch outline drawings
Switch outline drawings
Vacuum switch contact diagrams
Vacuum switch contact diagrams
Vacuum switch cross-sections
Vacuum switch cross-sections

YK extra-high-pressure auto-reset controls

Normally closed switches designed for CO₂ refrigeration and other applications requiring high-pressure protection above 800 psi.

  • A sealed stainless steel sensing element and steel outer shell protect the assembly. The switch resets automatically when pressure falls to the reset point.
  • Factory-set working pressures range from 1,305 to 2,610 psi (9–18 MPa). Threaded flare or brazed tube connections and plug-in terminals or wire leads are available.
YK extra-high-pressure auto-reset controls
Switch specifications
ParameterValue
Contact arrangementExtra-high-pressure auto-reset, normally closed
Working pressure1,305–2,610 psi (9–18 MPa)
Burst pressure10,440 psi (72 MPa)
Ambient temperature−30 to +80 °C
System medium temperature−50 to +120 °C
Electrical capacity125 VA at 24 VAC or 375 VA at 120/240 VAC
Dielectric strength, open contacts700 VAC for 1 s
Dielectric strength, terminal to shell2,000 VAC for 1 s
Switch outline drawings
Switch outline drawings
Extra-high-pressure switch cross-section
Extra-high-pressure switch cross-section
Normally closed contact diagram
Normally closed contact diagram

YK tolerances and model number guide

Use these tables to specify pressure tolerances, fittings and electrical leads.

The low-to-high pressure ratio equals the low setpoint divided by the high setpoint, multiplied by 100. Use a pressure reducer during testing to prevent pressure surges. Use water cooling when brazing brass-tube switches.

Pressure differential and minimum tolerance
Working pressure (psi)Low-to-high setpoint ratio (%)Minimum tolerance (± psi)
3–2950–703
30–8045–605
81–16050–707
161–24060–7510
241–35060–7015
351–45065–8015
451–50065–8020
501–80070–8025
Pressure differential and tolerances · Brazing and cooling arrangement
Pressure differential and tolerances · Brazing and cooling arrangement

Discuss your requirements

Share the cut-in and cut-out setpoints, reset type, contact load, refrigerant, and fitting or tube connection.

CONTACT AEP →